Ship and steel-structure coatings · Practical application guide
Ship & Steel Coatings: A Trial Guide
Track pigment concentration through components and mixed coating without changing the specified protective system.

Define the coating layer and exposure first
State whether the colorant is being evaluated in a primer, intermediate or finish coat. Identify atmospheric, splash or immersion service, and keep the coating manufacturer’s approved system authoritative. A hull, ballast tank and atmospheric steel structure cannot share a generic pigment recipe. This workflow addresses laboratory colorant evaluation rather than engineering a protective coating system.
Keep ordinary coloring oxide separate from active anticorrosive ingredients and lamellar MIO. Adding a red pigment to a product is not evidence that it retains the original coating’s qualifications or performance. Separate colorant and inhibitor roles; MIO barrier-pigment distinction
Read A/B ratios without converting volume into weight
A real product example is Jotun’s Penguard Express MIO 80, an atmospheric-service intermediate coat, whose cited TDS specifies 4 parts A to 1 part B by volume. That is a mixing instruction for the named complete coating, not a pigment dose or permission to modify it. Jotun TDS, product mixing ratio
Calculated scaling: a nominal 2.50 L combined component volume uses 2.00 L A + 0.50 L B. It does not mean 2.00 kg A + 0.50 kg B. If weighing is permitted, the manufacturer’s component densities or validated mass ratio are needed. Never infer the mass ratio from the printed volume ratio or from the density of the mixed paint.
Calculate pigment in a two-component laboratory formula
Separate training example, unrelated to Jotun’s composition: suppose a qualified laboratory system uses 800 g A + 200 g B by its specified mass ratio, and A contains 3% dry color pigment by mass. Pigment delivered = 800 × 0.03 = 24 g. In the 1,000 g combined paint this is 2.4%, not 3%.
| Ledger item | Illustrative amount | Meaning |
|---|---|---|
| Component A | 800 g | Contains the pigment in this example |
| Component B | 200 g | Retains the established mass ratio |
| Pigment within A | 24 g | Already included in A, not added again |
| Mixed coating | 1,000 g | 24/1,000 = 2.4% pigment |
If the colorant changes A’s reactive-resin content, the formulation owner must recalculate chemical equivalence and the approved component ratio. If it adds an inert carrier, account for that material too. A “top-up” pigment addition to a mixed commercial coating is not an acceptable shortcut.
Run a representative panel program
- Use the approved coating as the control. Write the colorant change, dose basis and carrier balance into the formulation sheet before mixing.
- Make the pigment dispersion in its designated component or vehicle using compatible equipment. Do not grind an already activated two-component coating unless that process is explicitly designed and approved.
- Measure component viscosity, grind and storage response. Mix the evaluation coating with its correct A/B ratio and follow the specified induction and working-time requirements.
- Apply control and candidate to equivalent prepared panels at the specified film build. Include a representative vertical orientation when examining sagging and leveling.
- Record substrate and ambient conditions, measured dry-film thickness and cure history. Apply subsequent coats through the approved sequence.
- Submit the full layer stack to the product’s required qualification. Retain the panel and mixed-batch identification.
Measure application changes instead of hiding them
Inspect hiding, entrapped air, pinholes, edge coverage and sagging alongside color. Marine and protective coating formulations require coordinated rheology and film build; BYK’s application guidance treats these as system demands. Protective-coating formulation context
Use an identical measurement geometry and surface condition when comparing cured color. Review cure, adhesion and intercoat compatibility separately. If a candidate needs a different spray setup or extra thinner to appear acceptable, document that as a process/formulation change for evaluation rather than concealing it in the color match.
Troubleshooting and approval boundaries
| Observation | Evidence to compare | Next step |
|---|---|---|
| Color shifts after mixing B | A/B records, component compatibility | Repeat a controlled mixed sample |
| Sag or pinholes change | Viscosity, air, film thickness | Reassess application with the control |
| Poor recoat adhesion | Cure and recoat conditions | Test the approved layer sequence |
| Good color, failed protection | Full-system qualification results | Hold the change; investigate coating system |
Color data do not qualify a pigment for immersion, drinking-water contact or a ship-specific approval. Those decisions concern the complete specified coating and applicable documentation.
Prepare an actionable inquiry
Send FUXIN the layer position, binder family, active pigment dose and denominator, processing route, component arrangement, target panel and required pigment documents. Keep application settings and protective acceptance with the coating manufacturer or responsible specialist.
Technical references
- Jotun: Penguard Express MIO 80 technical data sheet, 2 January 2025
- ICL / HALOX — Red iron oxide primer formulation
- Sibelco — Micaceous iron oxide
- BYK — Marine and protective coatings
Independent technical guidance used for this application overview. These references are not FUXIN project case studies or a substitute for a grade-specific technical data sheet.