Request a Quote
Menu ☰

UHPC decorative components · Practical application guide

Decorative UHPC: Pigment & Flow Trials

Calculate pigment without confusing binder and premix mass, then compare mixing response, flow and finished specimens.

Illustrative pigment application: UHPC decorative components.
Illustrative application image. Confirm the finished shade with physical samples.

Keep the qualified UHPC formula as the baseline

Start with a UHPC system already qualified for the component. Pigment is a formulation change to evaluate with the same mixer, fiber system and curing route. The NPCA 2026 architectural UHPC guide addresses solid and liquid pigments and the need to test their effect on the matrix. It does not provide one transferable FUXIN dosage. UHPC pigment and batching guidance

The tables below are calculation examples at 1%, 2% and 3%, not a recommended UHPC trial window. Use only levels accepted for your actual system. Preserve an unpigmented control and keep every water or admixture adjustment visible as a separate trial.

Do not confuse the two percentage denominators

If a test contains 12 kg qualifying cementitious material within 24 kg total dry premix, 240 g dry pigment is 2% of binder but 1% of total dry premix. Both statements describe the same mass. A source limit expressed on dry materials cannot be applied as though it used binder mass.

Calculation onlyDry pigment for 12 kg binderRate against 24 kg dry premix
1% of binder120 g0.5%
2% of binder240 g1.0%
3% of binder360 g1.5%

Here the dry-premix denominator is defined before pigment addition. State that convention in the record. Proprietary bag mass is not automatically cementitious mass; use the disclosed binder content or the supplier’s explicit premix-basis instruction. Do not replace cement with the calculated pigment.

Account for liquid color by actual composition

Liquid color mass = required dry pigment ÷ dry-pigment mass fraction. Water contribution equals liquid mass × verified water fraction. In this arithmetic example only, a suspension contains 60% pigment and 40% water; actual products may contain other solids or carriers.

Dry-pigment targetExample suspension requiredWater carried into batch
120 g200 g80 g
240 g400 g160 g
360 g600 g240 g

For the 240 g target, 160 g carrier water belongs in the existing batch-water budget. Do not add it on top and then call the formula unchanged. Re-homogenize the suspension before weighing. Liquid-color water accounting

Use a staged mixing record

  1. Record the starting material temperatures, mixer identity, load and time zero. Weigh pigment and each liquid independently.
  2. Use the UHPC system’s qualified charging sequence. NPCA’s described route introduces dry materials, then water/liquid superplasticizer, and fibers after fluidization; verify the pigment insertion point within that route. Manufacturing sequence
  3. At the agreed checkpoints, record elapsed time, temperature and the chosen flow measurement. Use the same test method and timing for baseline and colored batches.
  4. Keep the established fiber-addition and placement procedure. Photograph flow into a representative thin edge or relief, and inspect for fiber clusters and voids.
  5. If flow or temperature leaves the qualified range, stop and investigate. Do not restore a visual result with undocumented water.

Check the actual geometry and cure

FHWA notes that UHPC mixing energy, placement-dependent fiber behavior and curing affect performance. UHPC production background Make a component-like specimen and the required test specimens from the same trial. Record any thermal treatment as a complete cycle; this page assigns no generic pigment heat limit. Compare the finished dry face after the planned surface processing, and repeat the selected batch before release.

Troubleshooting and release

ObservationCheck firstNext action
Flow lower than baselinePigment mass, water ledger and dispersionRepeat under controlled batching; review a revised formula
Excess fluidity with liquid colorCarrier water counted twice or omittedCorrect the water calculation
Temperature rises fasterLoad, cycle and material temperatureReview mixer procedure and system limits
Fiber-rich marks or weak interfacesPlacement route and fiber distributionInvestigate and test representative pieces
Good color but failed propertiesUnqualified formulation changeReject the color recipe pending reformulation

Send FUXIN and the UHPC supplier the dry sample, exact denominator, liquid composition if used, flow/temperature records and test results. Release the combination only when appearance and specified UHPC performance both pass.

Technical references

Independent technical guidance used for this application overview. These references are not FUXIN project case studies or a substitute for a grade-specific technical data sheet.

Sample inquiry